FIBER OPTICS

From design to certification. End-to-end optical engineering.

Corporate backbones, data centers, industrial environments and high-capacity networks depend on optical infrastructure that can transport data with predictable performance and reliability.

ADD Solution works across the entire cycle: assessment, design, cable installation, assembly, splicing, termination, organization, identification, testing, certification and documentation.

With qualified professionals and specialized instrumentation, we turn the physical installation into measured, validated infrastructure ready to support operations.

APPLIED ENGINEERING

A reliable optical link must be designed, installed, measured and documented.

We deliver optical infrastructure with route engineering, splicing, termination, testing and certification aligned with the application.

Technician measuring and certifying a fiber-optic link

Architecture, implementation and operations treated as parts of the same responsibility.

BEYOND DEPLOYMENT

Installing fiber is one step. Delivering a validated link is the project.

A professional deployment connects design, routes, infrastructure, cable installation, placement, splices, terminations, identification, measurement, certification and documentation.

We do not deliver only a connected fiber. We deliver infrastructure whose condition can be measured, documented and validated.
OPTICAL DESIGN

Before installing the cable, we need to understand what the link must support.

Fiber is the medium. The design defines how it will support the network, considering application, capacity, topology, environment, expansion and interconnections.

01

Source & destination

Connected points, distances and areas.

02

Application

Capacity, speed and transported services.

03

Topology

Architecture, interconnections and redundancy.

04

Fiber type

Characteristics aligned with the application and its evolution.

05

Routes

Paths, environment and physical protection.

06

Terminations

Optical distribution frames, enclosures, connectors and organization.

07

Optical budget

Path contributions and required margin.

08

Documentation

Identification, results and traceability.

SINGLE-MODE

Application, optics and distance must work together.

OS1 and OS2 can serve different applications and distances depending on transceivers, standards, architecture, existing infrastructure and planned evolution.

MULTIMODE

Speed and reach are not simply a matter of “near or far.”

OM3, OM4 and OM5 have specific applications. Speed, distance, transceivers and total cost must guide the decision, with no universal hierarchy among fiber types.

OPTICAL BACKBONES

As capacity, distance and availability requirements grow, the backbone begins to define the network limit.

Fiber can support campuses, buildings, data centers, equipment rooms, industrial environments, distribution centers and corporate networks with capacity, scalability and immunity to electromagnetic interference.

Corporate Networks Industrial Networks Data Center
FIBER DEPLOYMENT

Fiber optics require care even before the first splice.

Routes, conduits, cable trays, enclosures, placement, bend radius, pulling tension, mechanical protection, service loops and identification influence the link’s final condition.

Final performance also begins with how the cable was installed.
BOXES, ODFs & TERMINATIONS

Physical organization is also part of reliability.

Optical distribution frames, enclosures, trays, pigtails, adapters, patch cords, service loops and identification support protection, maintenance, traceability, diagnostics and expansion.

OPTICAL SPLICING

Each splice becomes part of the optical path.

Preparation, cleaving, splicing, protection, placement, organization, identification and validation must form a single execution process.

Making the splice is an operation. Measuring the result is engineering.
CONNECTORS & CLEANING

A microscopic surface can cause a macroscopic problem.

Cleaning, inspection when applicable, and proper handling of connectors, adapters and patch cords reduce the risk of loss and instability caused by contamination or damage.

MEASUREMENT & CERTIFICATION

Optical infrastructure should not be approved merely because the link came up.

ADD Solution has instrumentation for measurement, analysis and certification according to the requirements, limits, methods and standards applicable to the project.

01

OTDR

Characterizes events and behavior along the link.

02

OLTS

Evaluates end-to-end optical loss using the applicable method.

03

Power meter

Measures power and supports optical loss testing.

04

Fusion splicer

Performs fusion splices with appropriate preparation and protection.

An active link answers: communication exists. Certification answers: the link meets the defined criteria.
OTDR

OTDR turns kilometers of fiber into a reading of link behavior.

The Optical Time Domain Reflectometer helps identify and characterize connectors, splices, reflections, localized losses, bends in certain scenarios, breaks and distance to events.

SOURCE ━ SPLICE ━ EVENT ━ CONNECTOR ━ DESTINATION
It does not show continuity alone. It helps indicate where the link is losing performance.
OLTS / POWER METER

Locating events and measuring total loss are complementary analyses.

Source, power meter, OLTS, insertion loss, wavelengths, reference and project limits enable end-to-end loss evaluation under the applicable method.

Different tools answer different questions.
OPTICAL BUDGET

Each component consumes part of the margin available to the link.

Fiber, distance, connectors, splices, splitters when applicable, and other elements contribute to total loss. The system power budget must not be confused with the infrastructure loss limit.

TX → CONNECTOR → FIBER → SPLICE → FIBER → CONNECTOR → RX
CONTINUITY, MEASUREMENT & CERTIFICATION

Light reaching the other end is not a certificate.

Continuity asks whether a path exists. Measurement observes behavior and loss. Certification verifies whether results meet the criteria defined for the link, application and applicable standard.

FAULT DIAGNOSIS

Replacing the entire cable should not be the first assumption.

Instrumentation makes it possible to investigate excessive loss, breaks, contamination, splices, bends, reflections, patching and physical degradation before intervention.

Measuring before intervening reduces trial and error.
REPAIRS & MAINTENANCE

Evidence-guided intervention.

ADD Solution can address breaks, splices, replacements, reterminations, reorganization, expansion, branches, diagnostics and recertification according to scope.

PHYSICAL REDUNDANCY

Two fibers on the same path may still represent a single dependency.

Logical redundancy and physical diversity are different concepts. When availability requires redundant paths, routes and shared points must be analyzed.

ROUTE APHYSICAL DIVERSITYROUTE B
SD-WAN & Connectivity
INDUSTRIAL ENVIRONMENTS

The physical medium must also suit the environment.

Distances, electromagnetic interference, routes, protection, topology, redundancy and integration guide the use of fiber without making it mandatory in every scenario.

Industrial Networks
DATA CENTER & HIGH CAPACITY

Optical interconnections support critical data paths.

Uplinks, backbones, storage networking where relevant, and connections between equipment and areas require design, organization and validation.

Data Center Servers & Storage
DOCUMENTATION & DELIVERY

A project ends better when it can be understood afterward.

Depending on scope, identification, maps, routes, source and destination, fibers, splices, terminations, results, reports and as-built documentation improve traceability, maintenance, diagnostics and expansion.

EXPERIENCE IN REAL ENVIRONMENTS

Optical infrastructure must adapt to context.

ADD Solution has experience in distribution and logistics centers, hospitals, industrial facilities and companies across different sectors, respecting their specific physical and operational requirements.

Explore the industries we serve

Your fiber is working. But do you know the link’s actual condition?

We can assess links, diagnose losses, locate events, verify terminations and take measurements to understand the actual condition of the infrastructure.

Request an assessment
ADD SOLUTION METHOD

From design to the final report.

Qualified professionals, OTDR, OLTS, power meters, fusion splicers and specialized instrumentation to handle the full deployment and validation cycle.

  1. 01

    Understand

    Application, environment and requirements.

  2. 02

    Design

    Topology, paths, fibers and terminations.

  3. 03

    Prepare

    Infrastructure and materials.

  4. 04

    Install

    Cable installation and placement.

  5. 05

    Splice

    Perform the required splices.

  6. 06

    Terminate

    Organize optical distribution frames, enclosures and interfaces.

  7. 07

    Measure

    Analyze optical behavior.

  8. 08

    Certify

    Validate according to applicable criteria.

  9. 09

    Document

    Record infrastructure and results.

  10. 10

    Deliver

    Make the validated infrastructure available.

CERTIFICATION EXPERTISE

We install. We measure. We certify. We document.

Certification and validation are conducted according to the requirements, limits, methods and standards applicable to the project. The technical equipment fleet includes instruments from different manufacturers.

Structured & Certified Cabling Technologies & Products
FREQUENTLY ASKED QUESTIONS

Important decisions about fiber optics

Objective answers to technical and operational questions that commonly arise before a project.

01Does an active link mean the link is certified?

No. Communication demonstrates functionality; certification verifies results against the criteria and limits defined for the project and application.

02Do OTDR and OLTS perform the same test?

No. OTDR characterizes events along the link. OLTS and a power meter evaluate end-to-end optical loss according to the test method.

03Is single-mode fiber always better than multimode?

No. Application, distance, speed, transceivers, existing infrastructure, evolution and total cost guide the choice.

04Does ADD Solution perform splicing and repairs?

Yes. The work may include splices, reterminations, reorganization, expansion, diagnostics, recovery and recertification according to scope.

05Do two fibers provide physical redundancy?

Not necessarily. If they share the same route and risk points, they may still represent a single physical dependency.

06What instruments does ADD Solution use?

The team has OTDR, OLTS, optical power meters, fusion splicers and specialized instruments from different manufacturers for implementation and validation.

TALK TO A SPECIALIST

Let's talk about Fiber Optics.

Share the context of your environment, the impact you are seeing and the outcome your organization is looking for. ADD Solution will route the conversation to the most suitable specialists.

CONVERSATION CONTEXTFiber Optics
ABOUT YOUR REQUESTYou are contacting ADD Solution about Fiber Optics.
SPECIALIST CONTACT

Turn your context into a clear next step.

Tell us what needs to evolve in Fiber Optics.

01
About youHow can we contact you?
* Required fields
Your data is sent securely and used only to respond to your request. See our Privacy Policy. · Terms of Use.