STRUCTURED & CERTIFIED CABLING

Your network’s reliability begins long before the first data packet.

A network infrastructure can use the best switches, servers, access points, and applications on the market. If the physical layer fails, everything else fails with it. ADD Solution designs, implements, organizes, tests, and certifies structured copper and fiber-optic cabling infrastructures for environments where availability, performance, and capacity for expansion are business requirements.

Talk to a specialist
ORIGEMDESTINO
ENLACE CERTIFICADO · PASS
CopperProfessional cabling and certificationFiber opticsDeployment, splicing and diagnosticsFluke NetworksCertified professionals
Our delivery does not end when the last cable is installed. It ends when we can demonstrate that the infrastructure is ready to operate within the parameters for which it was designed.
Measurable engineering

Installation is only one step. Demonstrating performance is what turns installation into engineering.

A cable may look well organized and still have termination faults, interference, signal loss or limitations.

ADD Solution measures and turns subjective quality into a measurable, documented result.

INSTALLED ≠CERTIFIEDDESIGNED + INSTALLED + TESTED + DOCUMENTEDPROVEN INFRASTRUCTURE
Fluke Networks

Quality demonstrated by those who implement and those who measure.

ADD Solution has Fluke Networks-certified professionals and professional instrumentation to assess, test and document copper links.

01

Fluke Networks-certified professionals

Specialized knowledge of testing and certification methods.

02

Professional instrumentation

DSX CableAnalyzer equipment turns performance into technical evidence.

DSX2-5000DSX-602DSX-602-PRODSX-PLA004S
We bring more than tools. We bring the engineering capability to verify the infrastructure.

A link provides much more information than simply “it works or it does not.”

Certifiers analyze electrical and transmission parameters and compare them with the limits of the selected standard.

01Wire Map
02Length
03Insertion Loss
04NEXT
05PS NEXT
06Return Loss
07ACR-N
08ACR-F
09Propagation Delay
10Delay Skew
11DC Loop Resistance
LINK RESULTPASS

The link either meets or does not meet the parameters established for the project.

Optical infrastructure

Fiber optics: from deployment to link characterization.

From cable installation through preparation, splicing, termination, organization, testing and documentation.

01

Fiber installation

02

Optical backbones

03

Splice and distribution enclosures

04

Optical distribution frames and terminations

05

Fiber splicing

06

Connectorization

07

Cleaning and inspection

08

Testing

09

Documentation

OLTS / Power meter

Measuring how much signal arrives is as important as knowing where it originated.

SOURCELINKPOWER METER

The measurement assesses insertion loss and end-to-end optical performance.

OTDR

Knowing that loss exists is not enough. We need to understand where it occurs.

The OTDR characterizes events and estimates positions along the link.

OLTS shows how much the link lost. OTDR helps determine where and how that loss occurred.

Precision is also measured in micrometers.

Preparation, cleaving, alignment, splicing, protection and organization require specific tools.

1Prepare2Clean3Cleave4Align5Splice6Protect7Organize8Test
Technical standards

Infrastructure built on standards, not improvisation.

Projects and tests consider applicable references; this does not represent institutional certification.

ABNT NBR 14565

Structured cabling in Brazil

ANSI/TIA-568

Cabling systems

ANSI/TIA-569

Pathways and spaces

ANSI/TIA-606

Administration and identification

ANSI/TIA-607

Bonding and grounding

ISO/IEC 11801

Generic cabling

IEEE 802.3

Ethernet applications

The cable is only one part of the infrastructure.

Design, pathways, racks, backbones, identification, measurement and documentation form a single system.

01Design02Physical infrastructure03Horizontal cabling04Backbones05Racks06Patch panels07DIOs08Identification09Certification10Documentation

From infrastructure to acceptance.

  1. 01

    Survey

    Analyze the environment and technical requirements.

  2. 02

    Design

    Define topology, distribution, routes and infrastructure.

  3. 03

    Size

    Plan for capacity, growth, density and performance.

  4. 04

    Implement

    Perform the physical implementation according to the design.

  5. 05

    Organize

    Organize racks, patch panels, optical distribution frames, fibers and pathways.

  6. 06

    Identify

    Standardize link identification.

  7. 07

    Test

    Perform applicable technical checks.

  8. 08

    Certify

    Instrumented measurement.

  9. 09

    Document

    Consolidate the results.

  10. 10

    Deliver

    Technical acceptance and documentation.

Traceability

The result should not depend on interpretation.

Reports, identification, acceptance evidence and history create a reliable foundation for maintenance and expansion.

CERTIFICATION REPORTPASS

Identified link
Verified parameters
Documented result

Different environments. The same reliability requirement.

Logistics

Organized, testable infrastructure prepared for connectivity and continuous operation.

Hospitals and healthcare

Organized, testable infrastructure prepared for connectivity and continuous operation.

Industry

Organized, testable infrastructure prepared for connectivity and continuous operation.

Corporate environments

Organized, testable infrastructure prepared for connectivity and continuous operation.

Execution quality

Certification does not fix a poor installation. It reveals it.

Bend radius, pulling tension, separation, routes, termination, identification and maintainability must be correct from the outset.

Certification is the final evidence of a correct process.

What are we really delivering?

Not only cables, connectors and racks. An infrastructure that connects:

PeopleApplicationsWi-FiTelephonyCamerasAutomationServersCloudCritical operations
Every digital transformation relies on physical infrastructure. That is where our work begins.

Your technology investment deserves infrastructure to match.

ADD Solution combines design, implementation, organization, testing, certification and documentation to deliver environments prepared to operate reliably today and continue evolving tomorrow.

Talk to a specialist
FREQUENTLY ASKED QUESTIONS

Structured cabling, certification and documentation.

Reliable physical infrastructure must be designed, installed, measured and delivered with evidence.

01What is the difference between testing and certifying a link?

A basic test can indicate connectivity. Certification measures parameters defined by the category and applicable standards, recording objective results for acceptance and traceability.

02Does certification replace a properly executed installation?

No. Certification demonstrates the performance achieved. Routes, bend radius, pulling tension, termination, organization, identification and separation must be handled correctly from installation onward.

03Can the project include copper and fiber optics?

Yes. The architecture can combine copper cabling, optical backbones, distribution frames, racks, terminations, splices and documentation according to distances, applications and environmental requirements.

04What information helps with the initial survey?

Floor plans, the number and location of outlets, planned applications, distances, available routes, environmental conditions, expected growth and acceptance criteria make sizing more accurate.

TALK TO A SPECIALIST

Let's talk about Structured & Certified Cabling.

Share the context of your environment, the impact you are seeing and the outcome your organization is looking for. ADD Solution will route the conversation to the most suitable specialists.

CONVERSATION CONTEXTStructured & Certified Cabling
ABOUT YOUR REQUESTYou are contacting ADD Solution about Structured & Certified Cabling.
SPECIALIST CONTACT

Turn your context into a clear next step.

Tell us what needs to evolve in Structured & Certified Cabling.

01
About youHow can we contact you?
* Required fields
Your data is sent securely and used only to respond to your request. See our Privacy Policy. · Terms of Use.