The XGS 4500 uses a 1U rack form factor and provides 4 × 1 GbE + 4 × 2.5 GbE + 4 SFP+ 10 GbE as fixed network interfaces. Consider this model when the network requires greater capacity in the 1U range and planning for redundant components. The appliance has dual SSDs with software RAID-1 support; a second internal power supply remains an option to be specified. The specification must distinguish integrated ports, optional modules and transceivers, and define licensing and continuity requirements.

Key features

Technical specifications

Performance
Firewall throughput80 GbpsHTTP traffic with 512 KB response size.
Firewall IMIX37 GbpsUDP mix of 66, 570 and 1518 byte packets.
Firewall latency (64-byte UDP)4 microsecondsMaximum throughput measured under ideal test conditions using Keysight-Ixia BreakingPoint; actual performance varies with network conditions and activated services.
IPS throughput36.5 GbpsIPS enabled with HTTP traffic, the default IPS ruleset and 512 KB object size.
Threat protection31.85 GbpsFirewall, IPS, application control and malware prevention enabled using Enterprise Mix traffic.
NGFW throughput30 GbpsIPS and application control enabled with HTTP traffic, the default IPS ruleset and 512 KB object size.
Concurrent connections17,200,000Maximum throughput measured under ideal test conditions using Keysight-Ixia BreakingPoint; actual performance varies with network conditions and activated services.
New connections per second450,000Maximum throughput measured under ideal test conditions using Keysight-Ixia BreakingPoint; actual performance varies with network conditions and activated services.
IPsec VPN throughput75.55 GbpsHTTP throughput using multiple tunnels and 512 KB response size.
Concurrent IPsec tunnels8,500Maximum throughput measured under ideal test conditions using Keysight-Ixia BreakingPoint; actual performance varies with network conditions and activated services.
Concurrent SSL VPN tunnels10,000Maximum throughput measured under ideal test conditions using Keysight-Ixia BreakingPoint; actual performance varies with network conditions and activated services.
Xstream SSL/TLS inspection10.6 GbpsIPS enabled on HTTPS sessions with different cipher suites.
Concurrent SSL/TLS connections276,480Maximum throughput measured under ideal test conditions using Keysight-Ixia BreakingPoint; actual performance varies with network conditions and activated services.
Hardware and environment
Local storage2 × minimum 240 GB SATA-III SSD (software RAID-1)Nominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Fixed Ethernet interfaces4 × GE copper; 4 × 2.5 GE copper; 4 × SFP+ 10 GE fiberNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Maximum port density28Nominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Idle power consumption151 W / 515.74 BTU/hNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Maximum power consumption268.35 W / 916.56 BTU/hNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Form factor and mounting1U rackmount; sliding rails includedNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Dimensions438 × 44 × 510 mmNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Weight9.7 kg unpacked; 15.9 kg packedNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Power supplyInternal hot-swappable auto-ranging AC-DC, 100–240 VAC, 3.7–7.4 A at 50–60 Hz; optional internal redundant PSUNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Operating temperature0°C to 40°CNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Storage temperature-20°C to +70°CNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Humidity10% to 90%, non-condensingNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Management ports1 × RJ45 MGMT; 1 × COM RJ45; 1 × Micro-USB (cable included)Nominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Other I/O ports2 × USB 3.0 frontNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Bypass pairs2Nominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Flexi Port slots2Nominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Optional Flexi Port modules8-port GE copper; 8-port GE SFP; 4-port 10 GE SFP+; 4-port GE copper bypass; 4-port GE copper PoE + 4-port GE copper; 2-port 10 GE NBASE-T + 2-port 10 GE SFP+; 2-port GE fiber LC bypass + 4-port GE SFPNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Maximum PoE via Flexi PortTwo Flexi Port modules: 4 ports and 60 W maximum eachNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
Optional connectivitySFP DSL module (VDSL2); SFP/SFP+ transceivers; transceivers sold separatelyNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
DisplayMulti-function LCD moduleNominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.
CertificationsCB, CE, UKCA, UL, FCC, ISED, VCCI, KC, RCM, NOM, Anatel, CCC, BSMI, TEC, SDPPINominal manufacturer specification; accessories, transceivers, redundancy and environmental conditions must be confirmed during design.